Avoiding manual explosion cleaningLausanne, Switzerland

Modernization of boiler cleaning at Kanadevia type WtE plant

No more manual explosion cleaning needed after installation of 2 P-WAVE generators in superheater section

Lausanne, Switzerland

Two P-WAVE generators are operating on Line 2 since August 2022 - positioned upstream superheaters 3 and 4. It is sufficient to operate them twice a week and tuned down to 350 bar (from from 600 bar). That way the plant maintains stable flue gas and boiler-outlet temperatures without organising manual explosion-cleaning campaigns. Once per year is largely sufficient for the exchange of the propane cylinder and maintenance of the P-WAVE generator and booster-compressor.

Boiler-upgrade with P-WAVE generators

P-Wave installation Lausanne.jpg

Installation at existing boiler access doors

Lausanne - installation at boiler acces doors.jpg

Interested in P-Wave for your boiler?

Talk to our team about your configuration and cleaning requirements.