P-Wave
Contact us
Boiler cleaning technology

Trouble with boiler fouling?

New options with automatic P-Wave generators!

Most effective high-power supersonic pressure waves — inherent safety without detonation of explosives.

100%
Manual explosion cleaning avoided
65%
Soot blower steam consumption reduced
15months
Outage intervals, extended from 12
150
Systems ordered since 2022 worldwide
15
Countries in operation
The challenge

Fouling remain among the biggest operational challenges in industrial boilers

Deposits on boiler tubes reduce the heat transfer. This is most severe in the case of firing of waste, biomass or other critical fuels. Resulting challenges are - increase of flue gas temperatures (most critcal: superheater inlet; boiler outlet) - need of manual explosion cleaning - increased corrosion rates - limited boiler service time and unplanned shutdown

The P-Wave Generator (PWG) was developed to solve exactly this problem — supersonic pressure waves remove deposits effectively, fully automatic and without detonation of explosives.

Technology

High-power supersonic pressure waves

Supersonic pressure waves are generated by combustion of propane with compressed air — no pure oxygen needed. These pressure waves are also called “power waves”, “shock waves” or “shock pulse”.

P-Wave generator

Fully automatic

An alternative to manual explosion cleaning. P-WAVE generators operate fully automatically and integrate into existing plant control systems. Overcome the safety and cost limitations of manual explosion cleaning systems.

Combustion without detonation of explosives

Super-high-pressure is generated by combustion of propane (~20 g/shot) mixed with highly compressed air (100 bar). The supersonic pressure wave is generated by the quick release of the pressure - the expansion of the gases is a separate process step independent of the combustion.

Adjustable pressure & power

Combustion pressures are typically set between 150 and 600 bar. The generator is designed and certified for 900 bar. Operators can program timing and strength, so cleaning is tuned to actual boiler requirements.

General principle of the P-Wave generator
1Close piston
Close piston
2Fill propane
Fill propane
3Fill compressed air
Fill compressed air
4Ignition / combustion
(typical: 600 bar; certified: 900 bar)
Ignition / combustion (typical: 600 bar; certified: 900 bar)
5Open piston (pneumatic actuator)
Open piston (pneumatic actuator)
Explore the technology
Full control

Change strength and frequency anytime

The power level and timing of the blasts are software settings in the controller — adjusted to match the actual fouling conditions. The blasts are typically released every two hours at pressures of 150–600 bar (certified to 900 bar).

“Can I change the strength and frequency of the pressure waves?”
“Yes — they’re settings in the controller. You can change them to adjust your dayly requirements. There is plenty of power reserve to reach the scheduled outage or increase of boiler load.”
Why P-Wave

Cleaning without contact, detonation or compromise

No detonation, no oxygen

New generation of powerful boiler cleaning! Supersonic pressure waves generated from combustion of propane with compressed air. No explosives or (pure) oxygen needed. Inherently safe and robust by design.

Fully automatic

Typically one programmed shot every ~2 hours, no operator presence required during operation. The P-WAVE controller cabinet (PLC) integrates with your DCS via hardwiring or bus connection.

Gentle on tubes

Least impacting option of boiler cleaning. No more damaging physical contact of hammers or steam/water jets with boiler tubes. Oxide layers remain untouched: Positive for reduced boiler tube corrosion rates!

Low operating cost

Very few consumables needed: 20 g of propane per blast as well as power for the compressor. This sums up per year to typically 100 kg propane and 1000 kWh (total of 500 €).

Stable flue gas temperatures

Consistently lower and stable flue gas temperatures before superheaters and at boiler outlet. Your gain: No more manual explosion cleaning, potential for increase of boiler load and service time.

Easy to maintain

Robust design for reliability and easy maintenance! Typically one overhaul per year with cost of 6000 € per generator. Potential to be reduced to 1500 € with training of local mantenance team.

See how P-Wave compares

Installed fleet

Where P-Wave generators run today

From waste-to-energy lines across Europe to large coal-fired units in Asia, P-Wave generators are at work across four continents. Each marker is an installation site - regions shown are indicative.

150+P-Wave systems in operation
256
Number of sites
In operation

See a P-Wave generator at work

Installed and firing in real plants — no test rig, no animation.

Waste-to-energy plant — Ferrara, Italy
Waste-to-energy plant — Böblingen, Germany
Waste-to-energy plant — Sharjah, UAE
Waste-to-energy plant — Lausanne, Switzerland
Waste-to-energy plant — Lausanne, Switzerland
Business case

Calculate your case in 2 minutes

Enter your operating profile and compare two P-Wave scenarios against your baseline — savings, generator count and payback. Indicative only; we follow up with a tailored review.

Estimate your case
The people behind it

Built on a legacy in boiler cleaning

Engineers and partners across the continents — building on the pressure-wave technology invented in Switzerland.

Meet the team
Contact

Talk to our team

Interested in a performance upgrade for your boiler? Get in touch and we'll discuss your configuration and cleaning requirements.

P-Wave AG
Gotthardstrasse 3, 5630 Muri, Switzerland
+41 56 611 98 18
hello@p-wave.ch